Accident Summary Nr: 200051118 - Two employees injured when scaffold towers overturn

Accident Summary Nr: 200051118 -- Report ID: 0728900 -- Event Date: 10/24/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30372515410/26/200017410Monona Masonry Inc.

Abstract: Employees #1 and #2 were erecting a Morgan scaffold consisting of two primary towers, a scaffold platform, and cross-bracing to prevent the scaffold towers from separating or falling apart. The base of each tower was shaped like an upside down T to prevent them from falling either toward or away from the adjacent wall. There were also cross-braces between the towers to prevent them from falling laterally and in unison. Employee #1 climbed one of the towers and Employee #2 climbed the other to replace a bent brace. While they were both at a height of approximately 20 ft, Employee #2, for some reason, removed the cross-braces on his side. The towers fell to the north, with both workers still on them. Employee #1 suffered three fractured ribs on his right side, a fractured upper right arm, and torn ligaments in his right shoulder that required surgical repair. Employee #2 suffered a fractured right knee, and multiple contusions and abrasions. Subsequent investigation revealed that neither employee had been trained to recognize the hazards associated with scaffold erection, as required by OSHA standards, and neither had the knowledge to work properly with the scaffold components. In addition, there was no competent person at the site directly supervising the scaffold erection process.

Keywords: ERECTION PROCESS, KNEE, FRACTURE, WORK RULES, CONSTRUCTION, FALL, BRACING, UNTRAINED, OVERTURN, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $250,000 to $500,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303725154 Hospitalized injury Fracture Occupation not reported
2 303725154 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.