Accident Summary Nr: 200033777 - Employee Is Killed When Crushed by Falling Granite Bundle

Accident Summary Nr: 200033777 -- Report ID: 0521700 -- Event Date: 12/30/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31515426012/30/20105032444190Primus Natural Stone Inc.

Abstract: At approximately 9:15 a.m. on December 30, 2010, Employee #1, a 23-year-old male Hispanic laborer, was working with a forklift truck operator to remove bundles of granite panels from a container. Each bundle contained 7 to 8 granite panels that varied in size and weight. The panels were not specifically arranged within the bundle. Thus, the larger (heavier) panels might have ended up on one side and caused a side-weighted condition. The container was arranged so that three bundles were in the rear of the trailer and four bundles were in the front. The bundles were held together with hardwood blocking, which formed a "case" for each bundle. Hardwood blocking was also used as support between the bundles, for the overseas trip. The removal process required some of the support blocking to be removed between each bundle and the bundles to be dragged from the container by a forklift truck. The bundles in the middle of the trailer could be immediately positioned between the 6-foot-long forks of the forklift truck and a chain was then attached to the forklift truck mast. The bundle was then dragged into the warehouse. Because there was initially no room to get the forks on both sides of the bundles along the container walls, those bundles had to be pulled out a certain distance, with the forks on one side of the bundle. Once the bundle had been pulled away from the wall, the forklift truck would then be repositioned, with one fork on each side of the bundle to be dragged into the warehouse. On this day, two of the rear bundles in the container had already been removed, and this left no additional support for the remaining bundle that weighed approximately 2.85 tons and was being pulled from the wall of the container. As Employee #1 entered the container to stabilize the bundle, the bundle fell across the forks, which were set approximately 2 feet above the floor of the container, and it crushed Employee #1 against the container wall. Employee #1 was killed.

Keywords: PANEL, INTERMODAL CONTAINER, CRUSHED, INDUSTRIAL TRUCK, OFF LOADING, STRUCK BY, TRAILER, FALLING OBJECT, UNSTABLE LOAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315154260 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close