Accident Summary Nr: 200033157 - Employee Dies from Asphyiation

Accident Summary Nr: 200033157 -- Report ID: 0521700 -- Event Date: 04/01/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31137270004/03/20083339331419International Titanium Powder

Abstract: At approximately 9:00 a.m. on April 1, 2008, Employee #1 was installing a filter on a vessel at a powdered metal process development site. The vessel measured about 60 inches deep, with a 48-inch diameter manhole on top. As Employee #1 installed the filter, he became asphyxiated and collapsed. He was discovered soon after by a coworker, who reported that Employee #1 was unconscious. Employee #1 died. The accident investigation revealed that Employee #1 was working alone in a confined space; no attendant was present. The cause of death was attributed to a lack of oxygen.

Keywords: CHEST, OXYGEN, OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, TOXIC ATMOSPHERE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311372700 Fatality Asphyxia Metallurgical and materials engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close