31136815309/18/20071771238990Jim'S Asphalt & Cartage, Inc.

Abstract: At approximately 6:00 p.m. on September 12, 2007, Employee #1 was refueling a Dynapak asphalt grinding machine. He had operated the machine during the day and, at the end of the shift, it was decided to refuel the machine from a small transfer tank. There had been some difficulty with removing the fuel cap because it was a rental machine with a locking cap and there was no key available. The cap was finally removed and Employee #1 had begun refueling when coworkers heard a sound; upon looking in the direction of the machine, they saw a large ball of flame engulf Employee #1 for a short duration. He climbed down from the machine and asked his father, who was the company owner, if his face was burned. He suffered serious burns over 65 percent of his body. Employee #1 seemed to be in shock, but he never lost consciousness and was able to climb into the ambulance without help. He was transported to the burn unit of Loyola Medical Center, where he died on September 17, 2007.

Keywords: BURN, COVER, DIESEL FUEL TANK, FLAMMABLE LIQUID, FLAMMABLE VAPORS, REFUELING, WORK RULES, FIRE, CONSTRUCTION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Maintenance or repair Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311368153 Fatality Burn(Chemical) Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Paving
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.