Accident Summary Nr: 200021822 - Employee killed in fall when crane rigging fails

Accident Summary Nr: 200021822 -- Report ID: 0214200 -- Event Date: 04/14/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30335023504/14/200017950Donjon Marine Co. Inc.

Abstract: At approximately 1:32 p.m. on April 14, 2000, Employee #1 was working on the rigging of a dockside, 550-ton container-loading crane. He was straddling a heavy duty, 7,020 lb chain that had just been tied off to the structural beams of the crane using multiple ties of 1 in. manila rope. Employee #1 was positioning the chain on top of the horizontal beam when the ropes used to tie the chain to the beam broke. The chain, which was still attached to the crane's load line, slipped off the beam and fell, causing the load line and chain to become taut. This resulted in Employee #1 being catapulted between 10 and 15 ft into the air and to be flung outward approximately 32 ft. He had already been working at a height of about 47 ft at the time the rigging failed, and fell altogether between 57 and 62 ft into a nearby parking are. Subsequent investigation revealed: 1) the manila ropes used to secure the chain to the crane were relatively new, but they failed after becoming chaffed and/or cut on the relatively sharp edges of the beam/steel plate to which they had been attached; 2) although the rope was said to have been inspected before its use, it was adequately inspected (as necessary) during its use to ensure it was safe. This was a violation of T8CCR 1926.251(a)(1); 3) the employee was not protected by a fall protection system, at the time of the accident, a violation of T8CCR 1926.501(b)(1); 4) the employee had not been trained in fall protection, and had not been given site training relative to fall protection and the applicable OSHA regulations. This was a violation of T8CCR 1926.21(b)(2) and 1926.503(a)(1).

Keywords: RIGGING, ROPE, WORK RULES, BROKEN CABLE, CONSTRUCTION, EQUIPMENT FAILURE, HOIST, FALL PROTECTION, UNTRAINED, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Demolition $50,000 to $250,000 1 47 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303350235 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 47 feet
Cause: Demolition
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.