Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200021368 - Two employees killed when elevator falls to basement

Accident Summary Nr: 200021368 -- Report ID: 0214200 -- Event Date: 05/13/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30213307905/13/199917960Admiral Elevator Corp.

Abstract: Employees #1 and #2 were dismantling a unused elevator and its related equipment in an industrial building. They were trying to lower the car from the fifth floor when it fell to the basement. Employees #1 and #2 sustained crushing injuries and were killed. They were working for an elevator maintenance company at the time of the accident.

Keywords: DISMANTLING, UNSECURED, WORK RULES, CONSTRUCTION, CRUSHED, FALL, ELEVATOR
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Other Under $50,000 5 60 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302133079 Fatality Other Specified mechanics and repairers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Elevator (struck by elevator or counter-weights)
2 302133079 Fatality Other Specified mechanics and repairers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Elevator (struck by elevator or counter-weights)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.