Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200012995 - Employee Is Killed By Exploding Drum

Accident: 200012995 -- Report ID: 0729300 -- Event Date: 10/28/2011
InspectionOpen DateSICEstablishment Name
31597984910/28/20111795Renovation Services Inc.

On October 28, 2011, Employee #1 used a cutting torch on a 55-gallon sealed drum that had contained a combustible liquid and might have still contained some of that liquid. The drum exploded, and Employee #1 was killed.

Keywords: burn, drum, construction, torch, explosion, combustible liquid, cutting and burning
Accident Details
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Other building Alteration or rehabilitation $500,000 to $1,000,000 2 X

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 315979849 Fatality Burn/Scald(Heat) Occupation not reported FallDist:
FallHt:
Cause: Demolition
FatCause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.