Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200012565 - Employee Is Killed in Trench Cave-In

Accident Summary Nr: 200012565 -- Report ID: 0729300 -- Event Date: 02/15/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31052850002/16/20071794238910P R Developers, Inc.

Abstract: At approximately 2:50 p.m. on February 15, 2007, an employee, a laborer, stepped out of the confines of a trench box he was working in and was struck by and partially trapped by unconsolidated material that fell from the nearly vertical trench side walls. The employee had been joining sections of 8 inch by 14 foot sewer line in the bottom of the excavation. The trench in which the employee was working measured approximately 11-ft deep, 3-ft wide and 25-ft long. The trench had been excavated by a Caterpillar track hoe, Model Number EL200B. Two coworkers immediately contacted emergency medical services. The rescue attempts were unsuccessful and the employee, after having been taken by EMS services to St. Francis Medical Center in Cape Girardeau, Mo., was pronounced dead.

Keywords: SAND, TRENCH, STRUCK BY, CONCUSSION, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant New project or new addition $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310528500 Fatality Concussion Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.