Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200012201 - Employee Is Caught in Auger and Dies

Accident Summary Nr: 200012201 -- Report ID: 0729300 -- Event Date: 05/10/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30727639405/10/20051771238990Concrete Paving Company Llc

Abstract: Employee #1 was tasked with cleaning the unguarded auger of a Model Number 2700 Slip Form Paving Machine with a power pressure hose. The hose became entangled in the spinning auger. Employee #1 was pulled into the auger and crushed to death.

Keywords: FRACTURE, CLEANING, CONSTRUCTION, HOSE, CRUSHED, AUGER, ENTANGLED, UNGUARDED
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street New project or new addition Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307276394 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Forming
Fatality Cause: Caught in stationary equipment

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close