Accident Summary Nr: 200010551 - ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

Accident Summary Nr: 200010551 -- Report ID: 0729300 -- Event Date: 07/23/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
10958337707/26/199907830The Shade Tree Service Company

Abstract: Some employees of a tree service firm were maneuvering an aerial lift truck in two adjacent backyards. They pulled out the strain relief on the telephone and cable television service cables to a house. To fix the problem, the employees started replacing the strain relief bolts. One of the employees was working from an insulated ladder while the other employee held it. The employee on the ladder apparently contacted an electric service conductor and was electrocuted.

Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, UNTRAINED, TREE TRIMMING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109583377 Fatality Electric Shock Groundskeepers and gardeners, except farm

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.