Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200002095 - Employee Killed by Heart Attack after Chemical Exposure

Accident Summary Nr: 200002095 -- Report ID: 0728500 -- Event Date: 11/07/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30809607211/08/20053442332321Rom Corporation

Abstract: After lunch on November 7, 2005, Employee #1 complained of chest tightness, heart burn, and trouble breathing. At approximately 1:30 p.m., a supervisor instructed him to go to the hospital. Employee #1 walked to his car, collapsed in the parking lot and died. Jackson County Medical Examiner determined the cause of death was a heart attack. Employee #1 had sprayed HDI-containing liquids for approximately five years prior to death. HDI is a sensitizer and can result in severe, life threatening asthma attacks due to hypersensitivity pneumonitis. The employer manufactured aftermarket automotive and truck panels and equipment. Two separate coating operations utilized isocyanate formulas as hardening agents. An automotive spray coating process used hexamethylene diisocyanate (HDI) and methylene bisphenyl isocyanate (MDI) containing hardeners during multiple two part paint applications. MDI was also used as the hardener in a large foam panel spray coating process that resulted in a bed liner type coated panel. Main hazards and issues involved employee respiratory and skin protection during exposure to HDI and MDI. Material safety data sheets were not maintained. The respiratory protection program was not appropriate for the exposure, respirator type, use of respirators, or fit testing. In addition, respirator use ranged from half face air purifying respirators to supplied air respirators with a hood and tight fitting full face piece.

Keywords: HEART, LUNG, PPE, HEART ATTACK, INHALATION, SPRAY PAINTING, PAINT, COATING OPERATION, CHEMICAL, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308096072 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.