Accident Summary Nr: 200002020 - Employee Is Killed While Repairing Hotel Dumbwaiter

Accident Summary Nr: 200002020 -- Report ID: 0728500 -- Event Date: 08/09/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30809429108/11/20057011721110Travelodge At The Falls

Abstract: On August 9, 2005, Employee #1, a maintenance worker for a hotel, was asked to repair a dumbwaiter that was stuck between the second and third floors of the hotel. As Employee #1 was examining the malfunctioning dumbwaiter, his head became pinned between a sheet of plywood attached to the lower half of the door to the dumbwaiter and a support bar at the top of the opening to the dumbwaiter. Two housekeepers discovered Employee #1 caught in the dumbwaiter and attempted to provide assistance, but he was already dead. The preliminary autopsy revealed that Employee #1 died from postural asphyxia.

Keywords: HEAD, MAINTENANCE, ASPHYXIATED, REPAIR, HOISTING MECHANISM, EQUIPMENT FAILURE, LOCKOUT, CAUGHT BETWEEN, ELEVATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308094291 Fatality Asphyxia Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close