Accident Summary Nr: 200001329 - Employee Struck by Wheel

Accident Summary Nr: 200001329 -- Report ID: 0728500 -- Event Date: 08/30/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30430399308/31/200134650Weld Wheel Industries, Inc.

Abstract: Employee #1 was operating a CNC lathe when the clamping device, which attached the wheel to the chuck, failed and projected the work piece and sections of the clamping device outward. The metal retaining cover was knocked off the machine by the force of the parts, striking Employee #1 fatally injuring him. Employee #1 was located in front of the lathe.

Keywords: WHEEL, LATHE, METAL SHEET, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 304303993 Fatality Bruise/Contus/Abras Machinists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.