Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 177943.015 - One employee is killed and another is injured by ruptured fr

Accident Summary Nr: 177943.015 -- Report ID: 0627500 -- Event Date: 01/27/2025
Inspection NrDate OpenedSICNAICSEstablishment Name
1800418.01501/28/2025213111Propetro Services Inc.

Abstract: At 6:00 p.m. on January 27, 2025, Employee #1 was assisting Employee #2 in checking a pump that was not getting suction during hydraulic fracturing operations. During this process, a frack line ruptured. Employee #1 died from multiple injuries. Employee #2 was hospitalized to treat the injuries sustained.

Keywords: Avulsion, Head, Hydraulic, Hydraulic Tool, Rupture, Torso

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1800418.015 43 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.