Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 174541.015 - Employee wearing supplied air respirator is asphyxiated whil

Accident Summary Nr: 174541.015 -- Report ID: 0729700 -- Event Date: 02/24/2025
Inspection NrDate OpenedSICNAICSEstablishment Name
1806145.01502/25/2025336411Textron Aviation Inc

Abstract: At 11:43 a.m. on February 24, 2025, Employee #1 was spray painting aircraft parts while wearing a supplied air respirator. Nitrogen back flowed into the breathing air system, displacing oxygen and causing the employee to be asphyxiated. Employee #1 was fatally injured.

Keywords: Fire, Fire Brigade/Department, Nitrogen, Oxygen, Respirator, Spray Booth, Spray Painting, Unconsciousness, Unresponsive

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1806145.015 61 M Fatality Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close