Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 174152.015 - Employee dies of cardiovascular disease, found unresponsive

Accident Summary Nr: 174152.015 -- Report ID: 0216000 -- Event Date: 02/08/2025
Inspection NrDate OpenedSICNAICSEstablishment Name
1803388.01502/10/2025484121Ashanti-I Trucking Corp

Abstract: At 9:02 a.m. on February 8, 2025, Employee #1 was working as a truck driver waiting in the cab of the truck at a repair shop when he was found unresponsive by a coworker (mechanic). It was determined that Employee #1 passed away due to natural causes. This is not covered by OSHA.

Keywords: Automotive Repair, Cardiovasc Disease, Cardiovasc System, Heart, Hypertension, Loss of consciousness, Lost consciousness, Lung, Medical Condition, Medical History, Natural Causes, Respiratory, Respiratory Tract, Truck, Truck Driver, Unconsciousness, Underlying Medical Condition, Unresponsive

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1803388.015 56 M Fatality Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close