Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 174117.015 - Employee is fatally injured while performing elevator inspec

Accident Summary Nr: 174117.015 -- Report ID: 0551800 -- Event Date: 02/06/2025
Inspection NrDate OpenedSICNAICSEstablishment Name
1803118.01502/07/2025333921Dc Elevator

Abstract: At 6:20 p.m. on February 6, 2025, Employee #1 was working as an electronics technician for an elevator and escalator supplier and was performing a routine maintenance inspection of an elevator. Employee #1 was found fatally injured on top of the elevator shaft.

Keywords: Asphyxiated, Compression, Compression Injury, Electronic Equipment, Electronic Technicn, Electronic Work, Elevator, Elevator Shaft, Engineering Controls, Falling Object, Fracture, Hemorrhage, Hoist, Hoisting Mechanism, Hoistline, Inspecting, Inspection, Insufficient Supervision, Lack of Engineering Controls, Lack of Work Procedures, Loss of consciousness, Lost consciousness, Maintenance, Multi-employer Worksite, Multiemployer, Shaft, Spine, Struck Against, Unconsciousness, Unresponsive, Vertebra, Working Alone

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1803118.015 51 M Fatality Electrical and electronic technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.