Accident Summary Nr: 173981.015 - Employee falls after unexpected release of pressurized gas d

Accident Summary Nr: 173981.015 -- Report ID: 0830600 -- Event Date: 12/31/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1802005.01502/03/2025482112Leadville, Colorado & Southern Railroad, Co.

Abstract: At 8:30 a.m. on December 31, 2024, Employee #1 was performing pre-start operations on a locomotive, specifically releasing pressurized diesel engine cylinders at approximately 300 PSI. During the operation, the employee was subjected to an unexpected release of pressurized gas while standing on the locomotive runway, which is about 5 feet above the adjacent ground. The employee fell between the runway platform and the handrail, impacting the ground. The employee was killed at the scene.

Keywords: Compressed Gas, Fall, Fall From Elevation, Fall Protection, Gas, Ground, Handrail, Locomotive, Pressure Release, Started

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1802005.015 30 M Fatality Operating engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close