Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 172152.015 - Employee dies from head trauma when struck by falling power

Accident Summary Nr: 172152.015 -- Report ID: 0950631 -- Event Date: 11/22/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1790038.01511/22/2024532412Bragg Investment Company, Inc.

Abstract: At 2:21 p.m. on November 22, 2024, an employee was working as a truck driver for a contractor that provides crane and rigging services and heavy load transportation. The employee was standing on the backside of a trailer truck in power company yard. A coworker (crane operator) was moving a 50-foot, 3,182-pound power pole onto the trailer using a Manitex Model 3051T Series C mobile truck crane. The coworker was attempting to move the power pole load while the employee was standing near the truck to guiding the load. The employee did not approve of how the pole was being loaded onto the truck. As the coworker moved the load on the trailer, the pole began tilting into a vertical position. The rigging failed allowing the pole to slip out of the sling. The pole bounced and struck the employee causing him to fall off the back of the truck and onto the asphalt ground striking his head. The employee died from crush injuries and head trauma.

Keywords: Asphalt, Blunt force, Blunt force trauma, Concussion, Crane, Crane Load, Crane Operator, Crushed, Fall, Fall From Elevation, Falling Object, Ground, Head, Hoist, Hoisting Mechanism, Hoistline, Load Shift, Loading, Material Handling, Misjudgment, Misjudgment of Hazardous Situation, Mobile Crane, Pavement, Rigging, Semi Tractor Trailer, Skull, Sling, Struck Against, Struck By, Tractor Trailer, Trailer, Trailer Truck, Truck Crane, Truck Driver, Unsecured, Unstable Load, Unstable Position, Utility Pole, Work Surface

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1790038.015 40 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.