Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 171110331 - Employee's fingertip amputated in power press

Accident Summary Nr: 171110331 -- Report ID: 0454510 -- Event Date: 12/11/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
30177443601/20/199837140Mckechnie Vehicle Components

Abstract: Employee #1, a press set-up operator at a wheel cover manufacturing facility, was making test runs of wheel cover parts on an Aida 200-ton part-revolution mechanical power press. He activated the two-hand trip, punched the first part, and was reaching into the point of operation when the ram topped out and then continued its downward motion. The die caught Employee #1's left middle finger, amputating the tip. After the clutch/flywheel was dismantled, it was found that one of the three bolts holding the flywheel shaft end plate in place had worked its way out. Apparently, the bolt had become jammed between the piston ribs and the friction plate, creating a mechanical connection between the flywheel and clutch shaft that resulted in excessive stroking. A wire connecting the three bolts had also been sheared.

Keywords: AMPUTATED, POWER PRESS, UNSECURED, FINGER, POINT OF OPERATION, BOLT, PRESS OPERATOR, PUNCH PRESS, MECH MALFUNCTION, RAM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301774436 Non Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close