Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 171057896 - Employee killed when struck by track of rolling dozer

Accident Summary Nr: 171057896 -- Report ID: 0854910 -- Event Date: 08/05/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30116109708/06/199916230Sterling Const Co

Abstract: Employee #1 was using a Caterpillar D-8H bulldozer to help to move other vehicles up a steep section of a pipeline right-of-way. The vehicles were attached by choker cable to the bulldozer and then pulled to the top. Employee #1 stopped the dozer on the steep grade, set the parking brake, and dismounted to hook up a bus he was going to pull to the top of the hill. He had been off the bulldozer for several minutes when the parking brake failed and the vehicle began to move downhill. Employee #1 tried to jump back onto the dozer but he became entangled in its track and was killed.

Keywords: BRAKE, WORK RULES, EQUIPMENT OPERATOR, CONSTRUCTION, EARTHMOVING EQUIP, EQUIPMENT FAILURE, STEEP GRADE, STRUCK BY, BULLDOZER, ENTANGLED
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $20,000,000 and over X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 301161097 Fatality Bruise/Contus/Abras Operating engineers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Traffic protection
Fatality Cause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close