Accident Summary Nr: 170899900 - ELECTRIC SHOCK - GROUND FAULT IN FILM PROCESSOR

Accident Summary Nr: 170899900 -- Report ID: 0950641 -- Event Date: 08/08/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12609340008/08/199678190Nat'L Film Lab. Dba Crest Nat'L Videotape & Film

Abstract: An employee entered a locked room to service a wet gate printing machine used for enhancing and duplicating reels of film. He was changing the filter on a perchloroethylene reservoir. The machine was connected to a homemade outlet box through two power supply cords and attachment plugs. Additionally, the machine was not grounded. (The equipment grounding conductors in the cords were not connected to an equipment ground at the outlet box. Apparently, a ground-fault energized the film processor, and the employee was electrocuted when he contacted it.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126093400 Fatality Electric Shock Photographic process machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close