Accident Summary Nr: 170893010 - Employee injured when burned by oil line explosion

Accident Summary Nr: 170893010 -- Report ID: 0950637 -- Event Date: 05/21/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30085508706/06/200216290Brinderson

Abstract: At 12:21 p.m. on May 21, 2002, Employee #1, a contractor welder, was injured when another nearby contractor employee began to torch cut an out-of-service crude oil pipeline in a tank farm area at a 250,000 barrel-per-day refinery. The 24-inch by 1000-foot long crude line had been drained and emptied, but had not been steamed, cleaned, or made gas free when the incident occurred. The incident occurred as the welder's helper began torch cutting the top west end of the crude line when a sudden explosion and subsequent fire occurred that injured Employee #1, the welder, who was nearby on the same work platform as the helper. Employee #1 was treated with first aid and subsequently hospitalized for medical treatment for first-and-second-degree burns to the face, hands, arms, back and legs and a third-degree burn to the right calf. No other employees reported injuries.

Keywords: BURN, FIRE, WELDING, EXPLOSION, PIPELINE, ARM, FACE, HAND, REFINERY, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery Alteration or rehabilitation $250,000 to $500,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300855087 Hospitalized injury Burn/Scald(Heat) Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close