Accident Summary Nr: 170892616 - Employee injured in fall from fixed ladder of cement truck

Accident Summary Nr: 170892616 -- Report ID: 0950632 -- Event Date: 08/10/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12601387908/23/199532730Superior Ready Mix Concrete

Abstract: At approximately 11:15 a.m. on August 10, 1995, Employee #1, who worked for a company that sold and delivered sand, gravel, and ready-mix cement, delivered a load of cement, then began to wash down a cement truck at the yard's wash basin with a water hose. He was descending the truck's 8 ft ladder at the left rear when his feet slipped from the fifth rung. He fell backward about 5 ft, landing first on his buttocks then slamming his head backward against the concrete. Having reportedly sustained a minor cerebral hematoma, Employee #1 was taken to Palomar Hospital. According to the employer, Employee #1 was properly trained with 19 years work experience. No defects were found with the equipment or procedures. No accident-related violation was discovered and no safety violations were observed during the inspection.

Keywords: HEAD, CONCRETE TRUCK, CLEANING, SLIP, DESCENDING, FIXED LADDER, FALL, SLIPPERY SURFACE, BRAIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126013879 Fatality Other Miscellaneous material moving equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close