Accident Summary Nr: 170870612 - Employee struck and killed by exploding tank

Accident Summary Nr: 170870612 -- Report ID: 0950625 -- Event Date: 07/26/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
11998174407/26/200192240North Central Fire Protection

Abstract: On July 26, 2001, Employee #1 was assigned to prepare the new fire truck for readiness and a training session. He was filling the truck's water tank through the discharge valve on the truck. The water was from the domestic water supply. The tank was filled about half full (400 gallons). There was a child present that was trying to squirt water out of one of the hoses. The water was not spraying well, so Employee #1 increased the pressure by running up the rpm on the engine. He must have forgotten about the hose hooked up to the discharge valve. The pressure increased in the truck tank and the water exited the discharge valve and over pressurized the domestic water supply tank. The bottom of the domestic tank ruptured and the 500-gallon tank went airborne about 100 ft and came down on the cab of the fire engine. Employee #1 entered the cab to shut off the engine. While inside the cab, the weight of the tank collapsed the roof and crushed him. He was struck in the head by the collapsing roof. Emergency medical personnel were able to remove from the cap and he was transported to the hospital. At the hospital, he died from the traumatic head injuries sustained in the accident.

Keywords: ROOF, COLLAPSE, PRESSURE VESSEL, STRUCK AGAINST, CRUSHED, EXPLOSION, FIRE TRUCK, PUMP, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119981744 Fatality Fracture Firefighting occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close