Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170868723 - Employee dies of asphyxia when buried by crushed rock

Accident Summary Nr: 170868723 -- Report ID: 0950651 -- Event Date: 02/03/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12568180902/04/199714420Martin Sand And Gravel

Abstract: Employee #1's clothing became tangled in a conveyor tail pulley shaft, causing the conveyor to stall. The system continued to operate, and he was covered with several tons of minus 1 in. crushed rock product. Employee #1 was buried about 15 minutes before he was rescued. Partial breathing was evident and he was transported to the hospital, where he was put on life support for two days. Employee #1 was pronounced dead at 2:27 p.m. on February 6, 1997.

Keywords: CLOTHING, ASPHYXIATED, ROCK, WORK RULES, CAUGHT BY, CONVEYOR, ENTANGLED, PULLEY, BURIED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125681809 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close