Accident Summary Nr: 170866693 - Employee injured between elevator platform and top of shaft

Accident Summary Nr: 170866693 -- Report ID: 0950621 -- Event Date: 07/21/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12580006007/21/199917960Otis Elevator Co.

Abstract: At approximately 1:00 p.m. on July 21, 1999, Employee #1, of the Otis Elevator Company, and a coworker were in a false car at the top of an elevator shaft, stringing six hoist cables between the counterweights, elevator car, and over the hoist motor pulley. When they had finished, they released the slings holding the counterweight at the top of the shaft, tensioning the hoist cables. The counterweights did not stop when the cables were tensioned but continued down the elevator shaft, gaining speed. As the counterweights moved down, the elevator car, which was only a framework, was going up the shaft. The top of the elevator car went through the bottom of the false car from which the employees were working. The coworker jumped off the platform onto the adjacent floor, but Employee #1 became caught on the platform and was pinned against the ceiling of the shaft. It took the local fire department over an hour to extract him. Employee #1 was then taken to the UC Davis Medical Center, where he was hospitalized with a fractured leg. The counterweight was found to be heavier then the elevator car frame, and it did not have a safety choker to prevent a runaway. The braking system on the hoist motor was not properly adjusted upon installation of the brake shoes, which were not in contact with the brake drum.

Keywords: SAFETY BLOCK, FRACTURE, HOISTING MECHANISM, COUNTERBALANCE, PINNED, WORK RULES, CONSTRUCTION, ELEVATOR, ELEVATOR SHAFT, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $20,000,000 and over 23

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125800060 Hospitalized injury Fracture Elevator installers and repairers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Elevator, escalator installation
Fatality Cause: Elevator (struck by elevator or counter-weights)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.