Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170856892 - Employee injured when wire rope sling broke

Accident Summary Nr: 170856892 -- Report ID: 0950653 -- Event Date: 04/03/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
12603794404/05/200110410C R Briggs

Abstract: Between 1:00 and 3:00 p.m. on March 22, 2001, Employee #1, an employee of C. R. Briggs Corporation, was assigned to a repair task at the crusher shop. At this mine site, C.R. Briggs Corporation operates an open pit gold mine located approximately 30 miles from Trona, California. Ore containing gold is extracted, crushed, leached in cyanide ponds, melted and the gold extracted and gold ingots cast on the mine site. Employee #1 and another mechanic were in the process of making weld repairs to a metal plate. The plate was approximately 50-inches in width by approximately 60-inches in height by approximately 5-inches in thickness, and weighing approximately 1600 pounds. Just prior to the injury, the metal plate was positioned on a concrete floor, standing vertically, and stabilized by a attaching a wire rope sling, approximately 0.25-inch by 36-inchs by 48-inches, to the metal plate and a boom truck. During a metal removal process called "air-arc", the wire rope sling was burned in two pieces. The wire rope sling was connected by a 0.60-inch screw pin shackle. The welding machine was set to between 400 and 450 amps. The factor that caused the accident was that the wire rope sling did not have the current carrying capacity to carry the amperage of the welder. The welder grounding electrode clamp was attached to the screw pin on the shackle. When the wire rope sling broke, the metal plate started to fall toward Employee #1. Employee #1 attempted to jump back, but the metal plate struck both his feet. The result was a broken right foot and the crushing of the left foot and ankle. Employee #1 was hospitalized with fractures.

Keywords: FRACTURE, WIRE ROPE, WELDER, METAL SHEET, STRUCK BY, SLING, ANKLE, FOOT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126037944 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close