Accident Summary Nr: 170853279 - Employee burned when flammable substance ignites

Accident Summary Nr: 170853279 -- Report ID: 0950631 -- Event Date: 11/23/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
12024739001/13/199917710David Paul Foster Company Inc

Abstract: Employee #1 was using a 110-volt electric drill to mix a flammable substance when the mixture ignited. He sustained burns to his arm, for which he was hospitalized.

Keywords: BURN, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, CONSTRUCTION, ELECTRIC DRILL, CHEMICAL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Maintenance or repair Under $50,000 1 12

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 120247390 Hospitalized injury Burn/Scald(Heat) Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.