Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170842553 - Employee injured when struck by headache ball

Accident Summary Nr: 170842553 -- Report ID: 0950611 -- Event Date: 01/10/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30089059701/11/200217910Wagner Construction Jv

Abstract: On January 10, 2002, Employee #1 was standing on the ground, next to a drilled "pier" foundation hole top casing. Employees were using a round steel pipe for temporary shoring and concrete forms. Another employee was operating a Grove 50-ton Hydraulic crane, Model number RT75S, Serial number 23246. The crane was positioned to extract the steel top casing from the ground. The crane operator, who was inexperienced, lowered the boom without laying out additional wire rope on the whip line. The headache ball two-blocked at the boom tip, parting the line, which allowed the ball to free fall and strike Employee #1 on the shoulder. The operator was not trained for this equipment and tested positive for marijuana. Employee #1 was hospitalized with a fractured left shoulder and ribs.

Keywords: FRACTURE, SHOULDER, CONSTRUCTION, RIB, STRUCK BY, TWO-BLOCKING, UNTRAINED, HEADACHE BALL, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $250,000 to $500,000 6 48

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300890597 Hospitalized injury Fracture Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.