Abstract: At approximately 2:00 p.m. on February 7, 2008, Employee #1 and a coworker were working as welders. They were employed by Irwin Industries Incorporated. They were welding at the Exxon Mobil Hill Lease in McKittrick, CA. They were tack welding a 356-millimeter (14-inch) slip-on flange onto a diatomite york scrubber inlet pipe. Serial number 2388g had been installed approximately 457 millimeters (18 inches) inside the pipe from the end where the welding operation was to be conducted. The purpose of installing the inflatable plug was to isolate any residual flammable gas in the pipeline from the welding process. Employee #1 had just completed tack welding the bottom of the flange to the end of the pipe and was tack welding the top of the flange, when the inflatable plug blew out of the pipe, striking Employee #1 in the head. Employee #1 was airlifted to the Kern Medical Center in Bakersfield, CA, for treatment. Employee #1 was admitted to the hospital intensive care unit due to complications after suffering numerous broken teeth, extensive lacerations to his head, mouth and throat area. Irwin ndustries Inc. reported this accident to the Cal OSHA Van Nuys District office the same day at 5:30 p.m. The Van Nuys District Office transferred the employer's report to the Cal OSHA So. Cal PSM District Office on February 8, 2007.

Keywords: FRACTURE, HEAD, GAS WELL, OIL WELL DRILLING, WELDER, WELDING, LACERATION, PIPE, STRUCK BY, PLUG ADAPTER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125915363 Hospitalized injury Cut/Laceration Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close