Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170809438 - Employees injured by fire and by jumping to avoid it

Accident Summary Nr: 170809438 -- Report ID: 0453730 -- Event Date: 12/17/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12522761112/18/199517110Protech Fabrication, Inc.

Abstract: Employees #1 and #2 were approximately 10 feet high on a scissor lift doing pipe fitting work on existing piping. Employee #2 had sawed off an existing pipe at the ceiling approximately 15 feet high. The pipe was drained of combustible liquid. Employee #1, a welder, put a short pipe nipple over the open end of the existing pipe and welded a first pass completely around the pipe with no problems. Employee #1 changed the welding rod, adjusted the welding machine, and began to weld the final pass. A small amount of combustible liquid in the pipe ignited and burned Employee #2. Both employees jumped to the floor. Employee #1 broke his heel.

Keywords: BURN, FRACTURE, WORK RULES, FIRE, WELDER, CONSTRUCTION, WELDING, COMBUSTIBLE LIQUID, PIPE, FOOT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125227611 Non Hospitalized injury Fracture Plumbers, pipefitters and steamfitters
2 125227611 Non Hospitalized injury Burn/Scald(Heat) Plumber, pipefitter and steamfiter apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close