Accident Summary Nr: 170762975 - Employee injured during scaffold collapse

Accident Summary Nr: 170762975 -- Report ID: 0950622 -- Event Date: 08/11/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
11980266808/24/199517210Chet Baker Painting

Abstract: At approximately 12:50 p.m. on August 11, 1995, Employee #1 and a coworker, the company owner, were working from a 12 ft high scaffold that rested on 2 in. by 6 in. pieces of wood. They were applying oil stain to the steeple section of a church. They used a 24 ft and a 40 ft ladder atop the scaffold to access the steeple and other areas of the building. Employee #1 stated that he was holding the 24 ft ladder while the coworker applied stain when the scaffold tipped and fell. Both employees fell with the scaffold. Employee #1 sustained broken ribs; he was hospitalized for several hours and released the same day. The scaffold had been erected without guardrails, bracing, or base plates, and the ladders were not tied, blocked, or otherwise secured.

Keywords: GUARDRAIL, UNSECURED, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, BRACING, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119802668 Non Hospitalized injury Bruise/Contus/Abras Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close