Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170761159 - Electric Shock - Contact with Overhead Line thru Boom

Accident Summary Nr: 170761159 -- Report ID: 0551800 -- Event Date: 07/19/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30405110507/19/20011542236220W.A. Sheets & Sons Inc.

Abstract: Employee #1 was working for a contractor, distributing concrete into a wall form from a concrete pump truck. He was standing on a two-plank bracket scaffold, located 3 meters above a lower level. The boom of the concrete pump truck was 0.9 to 1.2 meters from an overhead power line. Electric current arced from a phase conductor to the boom. Employee #1 was electrocuted.

Keywords: CONCRETE PUMP, ELECTRIC ARC, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CONCRETE TRUCK, ELECTROCUTED, E GI IA
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $50,000 to $250,000 3 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304051105 Fatality Electric Shock Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete foundations and walls
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close