12028410407/20/199417210Greenwell Painting

Abstract: Employee #1 and two coworkers were remodeling a mobile home. While the coworkers were in another area, Employee #1 was spraying lacquer (Mac Lac V-11) at 3/4 gallon/minute in the kitchen with a Graco Ultra 750 airless sprayer. Inadequate ventilation allowed the LEL to exceed 25 percent, and the high pressure (750 psi) of the lacquer sparked a flashfire. Employee #1 sustained 3rd-degree burns to the backs of her hands, 2nd-degree burns to her face, and 1st-degree burns to her thighs. The coworkers sustained minor injuries during their escape.

Keywords: BURN, VENTILATION, HAND BRAKE, LACQUER, WORK RULES, FIRE, CONSTRUCTION, PAINT, HIGH PRESSURE, FACE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120284104 Hospitalized injury Burn/Scald(Heat) Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close