Accident Summary Nr: 170727432 - Employee slips and cuts foot with chain saw
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 120288865 | 10/05/1994 | 4941 | 0 | Marin Municipal Water District |
Abstract: A MMWD crew was improving a water tank access road to make it an all-weather road. Employee #1, a laborer, was cutting down and bucking low-hanging tree limbs to provide clearance for road machinery. He was straddling the cut limbs, facing uphill, and bucking the limbs into lengths with a Husqvarna 24 in. chain saw. Two coworkers were working with equipment at the bottom of the slope out of view. Employee #1 was standing on wet grass and leaves. He slipped, and as he slid downhill, his left foot came up into the nose end of the chain saw. The blade cut through the boot and into the foot, lacerating the instep and damaging nerves. The slope was approximately 35 percent and covered by grass and trees.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120288865 | Hospitalized injury | Cut/Laceration | Laborers, except construction |