Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170717474 - Employee injured in fall through floor opening

Accident Summary Nr: 170717474 -- Report ID: 0950625 -- Event Date: 12/19/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12021360812/20/199416290Western Summit Constructors, Inc.

Abstract: At 11:30 a.m. on December 19, 1994, Employee #1, of Western Summit Constructors, Inc., was cleaning the base of the vertical north wall (I-line wall) rebar mat on the ground floor in preparation for the installation of a wall panel form. The 3 ft by 3 ft opening in the ground floor was located at a junction of the west wall and north wall, and was covered with plywood sheeting approximately 7/8 in. by 4 ft by 4 ft 6 in. The cover was not secured in place to prevent accidental removal and displacement, and markings on the cover were of faded, weathered, unreadable reddish paint. The ground floor opening was located over a dry pit 37 ft below the ground floor. Block cut form for the 3 ft by 3 ft ground floor opening had been removed. The bottom portion of the ground floor form had also been removed. This in effect now resulted in a through opening. During cleaning, Employee #1 raised or moved the plywood cover, for unknown reasons. Assuming that the bottom portion of the floor form was still in place, or forgetting that the floor had been removed, Employee #1 apparently stepped forward into the 2 ft by 3 ft opening and fell through 37 ft to the floor of the dry pit. Employee #1 sustained severe trauma to his left arm and hip. He was removed to Valley Medical Center for treatment and admission.

Keywords: FRACTURE, COVER, WORK RULES, CLEANING, CONSTRUCTION, FALL, FALL PROTECTION, FLOOR OPENING, ARM, HIP

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120213608 Hospitalized injury Fracture Carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close