Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170710370 - Employee's fingers amputated by press die

Accident Summary Nr: 170710370 -- Report ID: 0111500 -- Event Date: 08/31/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11321022308/31/199434690G & R Manufacturing Carlson Holdings Inc.

Abstract: On August 26, 1994, Employee #1 was operating a mechanical power press when his left hand was caught in the danger zone under the cutting die. Four of the employee's fingers were amputated. The press was equipped with a pull back device.

Keywords: PULL BACK DEVICE, DIE, AMPUTATED, POWER PRESS, FINGER, CAUGHT BY, POINT OF OPERATION, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 113210223 Hospitalized injury Amputation Rolling machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.