Accident Summary Nr: 170706196 - Employee is overcome by unexpected chemical fumes

Accident Summary Nr: 170706196 -- Report ID: 0950642 -- Event Date: 06/02/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11216140107/15/199334830Ni Industries Norris Division

Abstract: Employee #1, a maintenance mechanic in a TSD facility, was in the unloading area of the facility. Employee #1 was pumping hazardous acid waste drums into a holding tank using a hose attached to a tube, called a "stinger." In this procedure, the waste remaining in the drum is pumped down to the bottom 1 or 2 inches. The drum is then filled partially with water, and its contents are tipped into a containment pan. The drums are then rinsed several times into the pan. According to Employee #1, he pumped and rinsed 15 to 20 55-gallon drums and then pulled out three 30-gallon plastic drums. After he pumped out the first 30-gallon drum, he poured the rinse into the containment pan. A reaction occurred in the pan. Employee #1 started choking and went to the hospital, but fully recovered. (Employee #1 has a history of asthma.) Since hazardous waste labels were removed prior to dumping and rinsing, it is not certain what acids reacted. Two of the 30-gallon drums may have contained a sulfuric acid solution. A respirator was not worn because the drums were not labeled "fuming." Due to this accident, the employer established written drum-rinsing procedures to ensure that potentially hazardous material is removed from the containment pan before more waste is added.

Keywords: RINSE TANK, WORK RULES, DRUM, INHALATION, CHEMICAL REACTION, HAZARDOUS WASTE, TOXIC FUMES, OVEREXPOSURE, SULFURIC ACID, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112161401 Non Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close