Accident Summary Nr: 170705917 - Four employees injured when vapors in tank explode

Accident Summary Nr: 170705917 -- Report ID: 0855610 -- Event Date: 01/05/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
12520455201/06/199813110Kcs Mountain Resources Inc

Abstract: Employees #1 through #4 were working in the vicinity of an oil field storage tank. Earlier, a heater had been removed from the tank and repaired; it was moved to within approximately 18 in. of the tank, but reinstallation was postponed until a smokestack bracket was welded to the top of the tank. Escaping hydrocarbons from the 400-barrel tank were ignited by the welding operation, resulting in an explosion. Employee #1 sustained second- and third-degree burns over 30 percent of his body and was transported to a burn treatment center. Employees #2 and #4 were hospitalized for treatment of second-degree burns and a fractured leg. Employee #3 was treated for burns and released. Although the tank had been washed, no monitoring had been conducted for combustible vapors, hydrogen sulfide, or oxygen.

Keywords: BURN, VAPOR, FLAMMABLE VAPORS, WORK RULES, OIL WELL DRILLING, STORAGE TANK, WELDING, EXPLOSION, CHEMICAL VAPOR, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125204552 Hospitalized injury Burn/Scald(Heat) Welders and cutters
2 125204552 Hospitalized injury Burn/Scald(Heat) Welders and cutters
3 125204552 Non Hospitalized injury Burn/Scald(Heat) Laborers, except construction
4 125204552 Hospitalized injury Burn/Scald(Heat) Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.