Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170703532 - Employee injured in fall caused by counterweight

Accident Summary Nr: 170703532 -- Report ID: 0950626 -- Event Date: 08/24/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11194771912/03/199213890Rent-A-Hand Services

Abstract: On August 24, 1992, Employee #1 was working on Grayson Services Rig #18 at the Cymric Oil Field, Chevron Oil Lease, McKittrick, CA. During rigging down operations, the counterweight of the descent control device caught on a girt of the mast, causing the 3/16 in. cable of the counterweight to break. The counterweight rolled down the 1 in. cable to the draw works. Employee #1 stepped back as the counterweight hit the draw works, causing him to be pitched about 8 feet from the rig to the ground. He was taken to Mercy Hospital, in Bakersfield, CA, for treatment. Employee #1 sustained fractures to both wrists and his right hip.

Keywords: FRACTURE, COUNTERBALANCE, BROKEN CABLE, FALL, OIL WELL SERVICING, HIP, WRIST

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111947719 Hospitalized injury Fracture Helpers, extractive occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.