Accident Summary Nr: 170702039 - Employee dies, two injured, when exposed to cyanide fumes

Accident Summary Nr: 170702039 -- Report ID: 0950614 -- Event Date: 09/25/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11180785509/25/199333410K & L Plating Company

Abstract: At approximately 12:50 p.m. on September 25, 1993, Employee #1, a plater/maintenance worker for K&L Plating Company, was assisting Employee #2 in cleaning wastewater treatment tanks. Employee #2 entered tank G to remove sludge and water from its bottom using a wet/dry vacuum cleaner with hose and nozzle attachments. The vacuum had been previously used to clean a liquid acid/cyanide solution. The atmosphere inside tank G had not been tested for contaminants or oxygen content prior to the employee's entry. Employee #2 was overcome by cyanide fumes. Employee #1 entered the tank in an attempt to rescue Employee #2, but was himself overcome by the fumes. Employee #1 died and Employees #2 and #3 sustained serious injuries from their exposure to the fumes. Several other employees were overcome when they assisted in the rescue operation. Neither Employee #1 nor #2 were wearing the proper respirator or protective equipment when they entered tank G. If the employees were properly equipped and trained, the accident would have been prevented. Willful serious violation of 8CCR 5144 (a), 5159(a)(4), 5159(b)(1), 5158(c), 5157(b), and serious violation of 8CCR 3203(a)(4), 5159(a)(5), 5144(f)(1), 5194(f)(1), are determined to be accident related.

Keywords: VAPOR, CONFINED SPACE, WORK RULES, CLEANING, INHALATION, OVEREXPOSURE, TANK, CYANIDE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111807855 Fatality Asphyxia Metal plating machine operators
2 111807855 Hospitalized injury Poisoning(Systemic) Metal plating machine operators
3 111807855 Hospitalized injury Poisoning(Systemic) Metal plating machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.