Accident Summary Nr: 170670574 - Two employees die in barge explosion

Accident Summary Nr: 170670574 -- Report ID: 0419700 -- Event Date: 12/20/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11009708612/21/199437310Offshore Shipbuilding, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11013091112/20/199437310Offshore Shipbuilding, Inc.

Abstract: At the time of the explosion, Employees #1 and #2 were moving electrical lighting and spray painting equipment in the center compartment or hold of a 300 foot Bainbridge barge that was being built. Although 10 hours of painting had been completed, Employees #1 and #2 were preparing the holds for more painting. The paint had been mixed with methyl ethyl ketone (MEK) at a ratio of 4 1/2 to 5 gallons of MEK per 10 gallons of paint. There was no mechanical exhaust ventilation in the hold and one of the access holes to the hold was shut. No tests were done of the atmospheric conditions of the hold prior to entry. The electrical equipment in the hold (lights, flexible cords with splices and poor insulation, four receptacle outlets) was not approved for a Class I, Group D atmosphere. It is possible that when the employees were moving the equipment, an electrical spark ignited the explosion and fire. Employees #1 and #2 died.

Keywords: MEK, SHIPYARD, VENTILATION, CONFINED SPACE, FLAMMABLE VAPORS, FIRE, PAINT, EXPLOSION, SPARK, CHEMICAL VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110097086 Fatality Burn/Scald(Heat) Occupation not reported
2 110130911 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close