Accident Summary Nr: 170664205 - One employee killed, one injured in fall down elevator shaft

Accident Summary Nr: 170664205 -- Report ID: 0215000 -- Event Date: 06/05/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
11412462106/07/199617960Discovery Elevator Corp.

Abstract: Employees #1 and #2 were installing a 360 lb, 16 ft long guide rail in an elevator shaft. They were standing on a wooden work platform at the sixth floor level when the set of 2 in. by 4 in. by 7 1/2 ft supports on the right side collapsed. Employees #1 and #2 fell approximately 65 ft to the basement elevator pit. Employee #1 was killed and Employee #2 sustained multiple injuries. They were not wearing safety belts nor were they provided with any other means of fall protection. The employer had not examined the strength and structural integrity of the platform . to see if it could safely support the employees.

Keywords: COLLAPSE, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, FALL, FALL PROTECTION, ELEVATED WORK PLAT, WORK PLATFORM, ELEVATOR SHAFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114124621 Fatality Other Occupation not reported
2 114124621 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close