Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170632541 - One killed, one hurt from carbon monoxide in confined space

Accident Summary Nr: 170632541 -- Report ID: 0950644 -- Event Date: 01/22/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
11976680601/22/199717950Lu Mar Industrial Metals Co

Abstract: At approximately 9:50 a.m. on January 22, 1997, Employees #1 and #2 arrived at a demolition site to salvage the bottom part of a cardboard baler that was imbedded in an approximately 4 ft deep concrete pit. They uncovered the 29 in. by 38 in. opening to the pit and looked at the bottom, Both workers suffered from burning eyes, and Employee #1 went into the pit to investigate. He climbed up again to get a water hose because he said it was very hot down there. After putting the hose in the pit, Employee #1 went down again and Employee #2 followed. Both workers experienced chest tightness, difficulty breathing, and burning eyes, and decided to exit because of the intolerable conditions. Employee #2 climbed up first. Employee #1 was behind him, about halfway up the ladder, when he was overcome by the fumes and fell into the pit on his back. Employee #2 re-entered the pit to help Employee #1, who was already unconscious, but could not lift him up. Employee #2 then climbed out and asked workers of American Wrecking for help. Employee #1 was killed. Subsequent investigation revealed that on January 21, Employee #1 had used a cutting torch on a metal attachment and had started a fire the in the bottom of the pit. The flames had been put out by throwing down sand and dirt from the top of the pit. The fire was not completely extinguished and might have continued to smolder overnight, causing carbon monoxide to build up. This accident resulted from failure to follow well-established confined space work standards. The employer was cited for serious violations of T8CCR 5158(c)(1)(a); T8CCR 5158(d)(2); T8CCR 5158(d)(3); T8CCR 5158(e)(1)(b); and T8CCR 5158(e)(1)(e)(2).

Keywords: ASPHYXIATED, CONFINED SPACE, FIRE, CONSTRUCTION, INHALATION, PIT, CHEMICAL VAPOR, POISONING, OVEREXPOSURE, CARBON MONOXIDE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Demolition Under $50,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 119766806 Fatality Asphyxia Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Steel Erection Of Solid Web-Connecting
Fatality Cause: Asphyxiation/inhalation of toxic vapor
2 119766806 Hospitalized injury Asphyxia Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Steel Erection Of Solid Web-Connecting
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close