Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170631956 - Employee fatally crushed by falling machine

Accident Summary Nr: 170631956 -- Report ID: 0950642 -- Event Date: 10/22/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11216535210/22/199322690City Dyeing & Finishing

Abstract: Employee #1 was an employee of a dyehouse, where garments and piece goods are dyed. He was in the process of repairing Ellis Dye Machine #18. The Ellis Dye Machine (a washwheel) consists of a dye drum with three doors on one side through which materials are fed. The operation is similar to that of a household washer, but the drums are hydraulically raised during loading and unloading operations because of the machine's size. Employee #1 suffered fatal head and body fractures when he positioned himself underneath the machine and a loss of hydraulic pressure occurred, causing the drum to lower and crush him to death. The causal factors were the absence of a blockout/tagout procedure and the inoperability of the disconnect on the control panel.

Keywords: FRACTURE, REPAIR, WORK RULES, DRUM, LOCKOUT, CRUSHED, DYE MACHINE, DISCONNECTING MEANS, FALLING OBJECT, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112165352 Fatality Fracture Miscellaneous textile machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close