Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170627970 - Farm Workers Are Injured in Trailer Roof Collapse

Accident Summary Nr: 170627970 -- Report ID: 0950621 -- Event Date: 08/26/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
11991866208/26/20110171111333Stateline Farms Inc Dba Cedar Point Nursery

Abstract: On August 26, 2011, Employees #1 through #7 were riding a specialized trailer, lying in a prone position, picking fruit from strawberry plants. The trailer was suspended above the plants approximately 14 in. off the ground. The picked fruit would be loaded into large bins at the rear of the trailer. The two-wheeled trailer was pulled by a tractor and equipped with a roof for shade. The tractor's wheels were each mounted to its frame with brackets and four bolts. As the tractor reached the end of the field, it crossed a small elevated row. The additional stress on the loaded trailer caused the bottom two bolts from each wheel bracket to shear off. The trailer's rear end fell to the ground and its roof, which was not adequately secured, fell onto the seven employees. All of them were transported to a nearby hospital. Employee #1 was admitted for observation but did not sustain serious injuries. Employees #2 thru #6 were treated for minor injuries and released.

Keywords: ROOF, COLLAPSE, UNSECURED, AGRICULTURE, ABRASION, BOLT, STRUCK BY, TRACTOR, TRAILER, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119918662 Hospitalized injury Bruise/Contus/Abras Farm workers
2 119918662 Non Hospitalized injury Bruise/Contus/Abras Farm workers
3 119918662 Non Hospitalized injury Bruise/Contus/Abras Farm workers
4 119918662 Non Hospitalized injury Bruise/Contus/Abras Farm workers
5 119918662 Non Hospitalized injury Bruise/Contus/Abras Farm workers
6 119918662 Non Hospitalized injury Bruise/Contus/Abras Farm workers
7 119918662 Non Hospitalized injury Bruise/Contus/Abras Farm workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close