Accident Report Detail

Accident Summary Nr: 170620975 - Employee injured in fall into re-cutter machine

Accident Summary Nr: 170620975 -- Report ID: 0950622 -- Event Date: 02/08/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
11980095106/14/199626210Nelson Ball Paper Products, Inc.

Abstract: On February 8, 1996, Employee #1 was operating a Paco re-cutter machine, model SAR 42, that had eight 6 in. diameter circular knives set on a mandrel. He was cutting 32 in. long by 7/8 in. diameter paper tubes into 4 3/4 in. lengths when he fell into the unguarded rotating blades. Employee #1 suffered stomach lacerations, for which he was hospitalized. He had removed the machine's guard because of a loose screw,

Keywords: GUARD, ROTATING KNIFE, WORK RULES, LACERATION, FALL, STOMACH, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119800951 Hospitalized injury Cut/Laceration Slicing and cutting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.