Accident Report Detail
Accident Summary Nr: 170593560 - Employee #1 left thumb amputated in power press
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 119998276 | 05/24/1994 | 3444 | 0 | Moore Spring Co Inc Dba Moore Industries |
Abstract: At 10:00 a.m. on January 26, 1994, Employee #1, a 43-year-old machinist, amputated his left thumb while operating a power-operated press. Employee #1, a newly trained employee, was pressing one and one-half inch flat washers into a concave shape when his thumb entered the unguarded point of operation. Employee #1 sustained an amputation of the distal phalanges of the left thumb. The machine involved in the accident was a Rousselle 3G Punch Press. The shop foreman had performed the training and initial observation of the machinist about one and one-half hours prior to the accident.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119998276 | Hospitalized injury | Amputation | Punching and stamping press machine operators |
Translate