Accident Summary Nr: 170591895 - Employees exposed to ethylene oxide

Accident Summary Nr: 170591895 -- Report ID: 0950633 -- Event Date: 06/07/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
11990119706/07/199580620Riverside Community Hospital

Abstract: Employee #1 responded to an ethylene oxide (ETO) leak in the tank room of the sterile processing department of a general and surgical hospital. Employee #1 entered the tank room with an uncalibrated ETO sensor to determine the location of the leak. The employer did not provide nor did Employee #1 wear any respiratory protection. Once Employee #1 entered the tank room, the sensor alarm sounded and he left immediately. The leak was due to an improperly loaded gas sterilizer and a piece of cloth that became caught between the sterilizer door frame and door seal. Employees #1 and Employee #2, who also worked in the sterile processing department, were exposed to an unknown concentration of ETO.

Keywords: PPE, ETHYLENE OXIDE, WORK RULES, AIR CONTAMINATION, GAS LEAK, OVEREXPOSURE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119901197 Non Hospitalized injury Other Supervisors, cleaning and building service workers
2 119901197 Non Hospitalized injury Other Nursing aides, orderlies, and attendants

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close